Polaris Plate Heat Exchanger Replacement Gaskets
Explore replacement sealing options for selected Polaris S-series plate heat exchangers. Our historical model reference includes 29 entries, covering compact and larger plate-pack configurations with recorded port-center measurements.
A correct replacement must match the original plate groove, port sealing route, fastening features and fluid requirements. Model suffixes and mechanical retention details are particularly important when identifying existing Polaris equipment.
Request Polaris Gasket Quote →
-
Polaris Viton GasketsOEM-compatible FKM gaskets for confirmed Polaris plate heat exchanger modelsview more
Designed for selected high-temperature and chemically demanding process duties
Profile matching covers sealing ribs, port rings and attachment... -
Polaris NBR GasketsOEM-compatible NBR gaskets for confirmed Polaris plate heat exchanger modelsview more
Commonly selected for compatible oil and industrial utility applications
Profile matching covers gasket grooves, port rings and retaining... -
Polaris EPDM GasketsOEM-compatible EPDM gaskets for confirmed Polaris plate heat exchanger modelsview more
Suitable for compatible water-based heating and cooling applications
Profile matched by model, plate code, dimensions or physical sample... -
Polaris Compatible GasketsOEM-compatible gaskets developed for confirmed Polaris plate heat exchanger modelsview more
Profile matching covers sealing ribs, port rings and attachment points
Model identification supported by nameplate, plate dimensions or... -
Polaris Replacement GasketsOEM-compatible Polaris replacement gaskets for scheduled PHE maintenanceview more
Profile matching based on exchanger model, plate code or physical sample
NBR, EPDM and FKM compounds available for different process... -
Polaris Plate Heat Exchanger GasketsOEM-compatible replacement gaskets for Polaris plate heat exchanger maintenanceview more
Profile and attachment method matched to the confirmed Polaris plate model
NBR, EPDM and FKM material options for different process...

Replacement Seals for Existing Polaris Plate Packs
Polaris gasket identification begins with the installed plate pack. The exchanger model provides an initial reference, but the actual gasket must follow the correct port and perimeter sealing profile.
The historical WTSML range contains Polaris S-series references covering compact and larger plate designs. Mechanical fastening features, groove geometry and fluid conditions must be confirmed for each enquiry.
- Independent aftermarket gasket supply
- Historical Polaris S-series model references
- Sealing for demountable plate exchangers
- Glued and mechanical fixing options
- Model-specific profile and material verification
Similar S-Series Model Names Do Not Prove Interchangeability
Some Polaris model references overlap with S-series designations used in other plate heat exchanger spare-part catalogs. Similar naming may help locate a reference, but cannot confirm that the seal will fit.
The complete equipment nameplate, original gasket contour and plate markings should be compared before approving any proposed substitute component.
- Confirm the original equipment brand.
- Record the complete S-series model suffix.
- Inspect plate grooves and hanging features.
- Check port-ring geometry and gasket orientation.
- Verify replacement details against the actual sample.


NBR, HNBR, EPDM and FKM Material References
The historical Polaris product description lists NBRB, NBRP, HNBR, EPDM, HT EPDM and Viton A, B and G. Each refers to a material or historical grade option that requires verification.
The operating fluid, temperature variations, chemical additives and cleaning process must be reviewed before a specific compound is selected.
- NBRB / NBRP: historical nitrile references
- HNBR: hydrogenated nitrile elastomer family
- EPDM: consider for compatible water-based duties
- HT EPDM: grade-specific temperature confirmation
- Viton A / B / G: fluoroelastomer references
Polaris S-Series Gasket Model and HC/VC Dimensions
The tables preserve all 29 model entries supplied for this product family. HC means horizontal port-center spacing and VC means vertical port-center spacing. All figures are recorded in millimeters.
These historical dimensions support preliminary identification only. They are not certified plate or gasket drawings and do not independently establish compatibility.
Polaris S4A to S22
| Polaris Model | HC (mm) | VC (mm) |
|---|---|---|
| S4A | 70 | 381 |
| S7A | 126 | 394 |
| S8A | 70 | 656 |
| S8 | 70 | 656 |
| S15 | 126 | 694 |
| S19A | 192 | 700 |
| S20 | 126 | 894 |
| S20A | 126 | 894 |
| S21 | 225 | 719 |
| 21A* | 225 | 719 |
| S22 | 225 | 719 |
Polaris S30 to S50
| Polaris Model | HC (mm) | VC (mm) |
|---|---|---|
| S30 | 202 | 950 |
| S35 | 280 | 800 |
| S37 | 238 | 1441 |
| S38A | — | — |
| S39 | 202 | 1150 |
| S41 | 296 | 890 |
| S41A | 296 | 890 |
| S43 | 395 | 791 |
| S47 | 225 | 1365 |
| S50 | 202 | 1450 |
Polaris S62 to S121
| Polaris Model | HC (mm) | VC (mm) |
|---|---|---|
| S62 | 296 | 1292 |
| S64 | 225 | 1771 |
| S65 | 395 | 1091 |
| S65A | 395 | 1091 |
| S81 | 480 | 1080 |
| S100 | 395 | 1489 |
| S120 | 480 | 1490 |
| S121 | 480 | 1490 |
Hang-On, Lock and Snap Retention Considerations
Polaris aftermarket parts catalogs describe different mechanical fixing systems for certain S-series models. These include hang-on, locking and snap-style configurations.
A gasket cannot be selected merely by rubber material or port spacing. The attachment design must match the original plate-edge and groove features.
- Check whether the original gasket is glued.
- Inspect clips, tabs and fastening slots.
- Identify any proprietary locking geometry.
- Photograph corners and port-ring connections.
- Confirm the actual retention type before ordering.


Recognize the Correct Gasket Fixing Features
When a legacy plate pack is opened, the original seal provides important physical evidence. Clips, locating tabs, groove shape and gasket orientation should be recorded before the old component is discarded.
If the exchanger model is uncertain, photographs and measured dimensions may help narrow the matching options. A physical sample may still be necessary for final confirmation.
- Photograph the entire removed gasket.
- Record full plate and frame markings.
- Check the gasket route around each port.
- Identify glue residue or mechanical fasteners.
- Confirm the required compound and quantity.
Request Polaris S-Series Replacement Gaskets
Send the complete Polaris model and nameplate, original plate and gasket photographs, fixing method, process fluid, operating temperatures, required material, quantity and delivery destination for a replacement review.
Submit Polaris Gasket RFQ →Reduce Incorrect Spare-Part Orders During Shutdown Planning
For plants operating several generations of plate heat exchangers, a maintenance schedule may involve similar S-series model names with different actual sealing components.
A clear spare-part list should distinguish each exchanger by nameplate, plate-pack configuration, gasket compound and retention type. This reduces uncertainty when preparing a replacement order.
- Maintain a separate record for each installed unit.
- Confirm the number of plates and gasket sets.
- Identify any special end-position seals.
- State the planned shutdown date.
- Agree delivery and documentation requirements.

Three Verification Steps Before Ordering
01. Equipment Identity
Confirm the actual brand, complete S-series model, nameplate details and any relevant plate markings.
02. Gasket Specification
Verify physical fit, retention features, compound formulation, fluids and operating conditions.
03. Order Conditions
Agree quantity, inspection requirements, material records, delivery schedule and warranty terms for the specific order.
Frequently Asked Questions
1. Are these original Polaris OEM gaskets?
No. This category describes independent aftermarket replacement gaskets. Polaris names are used to identify existing equipment.
2. Can Polaris and SONDEX gaskets with similar model names be interchanged?
Not based on the model name alone. The original equipment, plate profile, gasket groove, fastening features and sealing route must be compared before compatibility can be confirmed.
3. What do HC and VC mean in the Polaris model table?
HC is horizontal port-center spacing and VC is vertical port-center spacing, as recorded in millimeters in the historical model data.
4. Can every Polaris gasket use the same clip-on or lock system?
No. Retention methods vary by the actual plate construction. The replacement must match the original fixing features or an approved alternative.
5. What information should be submitted for a Polaris gasket quote?
Provide the full model, nameplate, original gasket and plate photos, material requirement, fluid and temperature conditions, order quantity and destination.
Replacement Gaskets, Plates and Complete Heat Exchangers
During replacement work, inspect the plate grooves, corrugated surfaces and frame condition. A new gasket will not necessarily resolve leakage caused by damaged metal components or incorrect plate-pack assembly.
As one of the most professional polaris gaskets manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. We warmly welcome you to wholesale advanced polaris gaskets made in China here from our factory. Customized orders are welcome.