Bell & Gossett GPX Replacement Gaskets
Source independent replacement gaskets for selected Bell & Gossett GPX plate-and-frame heat exchangers. The model range includes compact units, industrial GPX configurations and legacy equipment requiring careful part identification.
We review the original plate profile, port sealing pattern, gasket fastening method and service fluid before confirming a replacement specification. NBR, HNBR, EPDM and selected fluoroelastomer options can be assessed by application.
Request GPX Gasket Quotation →
-
Bell & Gossett Viton GasketsOEM-compatible FKM (Viton®) replacement gaskets manufactured by WTSML for Bell & Gossett plate heat exchangers in chemically treated HVAC and hydronic systems.view more
Suitable for applications exposed to glycol solutions, corrosion... -
Bell & Gossett NBR GasketsOEM-compatible NBR replacement gaskets manufactured by WTSML for Bell & Gossett plate heat exchangers installed in pumped hydronic and HVAC circulation systems.view more
Designed to maintain sealing stability under pump vibration,... -
Bell & Gossett EPDM GasketsOEM-compatible EPDM replacement gaskets manufactured by WTSML for Bell & Gossett plate heat exchangers operating in commercial HVAC and hydronic systems.view more
Designed to maintain sealing stability during repeated seasonal heating and... -
Bell & Gossett Compatible GasketsOEM-compatible gaskets manufactured by WTSML for Bell & Gossett plate heat exchangers installed in commercial HVAC and hydronic systems.view more
Designed to simplify procurement, standardize maintenance inventory and support... -
Bell & Gossett Replacement GasketsOEM-compatible replacement gaskets manufactured by WTSML for Bell & Gossett plate heat exchangers used in commercial HVAC and hydronic systems.view more
Designed for preventive maintenance programs that reduce unexpected shutdowns and... -
Bell & Gossett Plate Heat Exchanger GasketsOEM-compatible replacement gaskets manufactured by WTSML for Bell & Gossett plate heat exchangers used in commercial HVAC and chilled water systems.view more
Precision-molded to ensure reliable sealing, consistent plate compression and...

Matching Seals to Bell & Gossett GPX Plate Packs
GPX gasket selection should begin with the installed heat exchanger configuration. Each replacement needs a sealing profile suited to the original plate and port arrangement.
The model alone may not identify every variation within an equipment family. Existing plate drawings, gasket samples and frame details provide valuable matching evidence.
- Independent aftermarket gasket supply
- GPX model and frame identification
- Port-ring and channel-perimeter sealing
- Glued or mechanically retained configurations
- Fluid and elastomer compatibility review
Port Seals, Vent Paths and Fluid Separation
Bell & Gossett GPX equipment documentation describes a molded gasket arrangement with sealing regions around the ports and across the heat-transfer area. Certain designs include vented sections between the sealing boundaries.
These details matter when replacing a worn gasket. Incorrect port rings or a different leak-path configuration can affect how the assembled plate pack contains its fluids.
- Compare all port-ring shapes.
- Inspect the plate groove for damage.
- Identify vented gasket sections where applicable.
- Record the flow arrangement and plate orientation.
- Do not assume a similar-looking seal has the same routing.


Choose the Gasket Compound for the Actual Medium
Historical WTSML references list NBRB, NBRP, HNBR, EPDM, HT EPDM and Viton A, B and G. Each requires grade-level confirmation.
The correct elastomer depends on the circulating fluid, concentration, operating and transient temperature, cleaning chemicals and the equipment specification.
- NBRB / NBRP: nitrile-grade references
- HNBR: hydrogenated nitrile elastomer
- EPDM: evaluate for compatible water-based circuits
- HT EPDM: confirm grade-specific thermal limits
- Viton A/B/G: historical fluoroelastomer references
Bell & Gossett GPX Model and Port-Center Reference
The following HC and VC figures reproduce the historical data supplied for this category. HC denotes horizontal port-center spacing; VC denotes vertical port-center spacing. All dimensions are in millimeters.
These values are preliminary identification aids, not certified manufacturing or installation drawings. Frame suffixes and special plate arrangements may require additional checks.
GPX8 to GPX120
| Bell & Gossett Model | HC (mm) | VC (mm) |
|---|---|---|
| GPX8 | 70 | 656 |
| GPX8a | 70 | 656 |
| GPX15 | 126 | 694 |
| GPX20 | 126 | 894 |
| GPX20a | 126 | 894 |
| GPX30 | 202 | 950 |
| GPX34 | 60 | 357 |
| GPX38 | 238 | 1070 |
| GPX39 | 202 | 1150 |
| GPX50 | 202 | 1450 |
| GPX65 | 395 | 1091 |
| GPX100 | 395 | 1436 |
| GPX120 | 480 | 1490 |
GPX130 to GPX646
| Bell & Gossett Model | HC (mm) | VC (mm) |
|---|---|---|
| GPX130 | 130 | 591 |
| GPX151 | 140 | 640 |
| GPX161 | 140 | 640 |
| GPX237 | 225 | 719 |
| GPX258 | 234 | 703 |
| GPX258B | 225 | 719 |
| GPX463 | 290 | 1046 |
| GPX538 | 365 | 930 |
| GPX538B | 365 | 930 |
| GPX646 | 298 | 1294 |
GPX678 to GPX1980
| Bell & Gossett Model | HC (mm) | VC (mm) |
|---|---|---|
| GPX678 | 298 | 1294 |
| GPX807 | 350 | 1315 |
| GPX850 | 365 | 1450 |
| GPX850B | 365 | 1450 |
| GPX915 | 353 | 1478 |
| GPX1152 | 430 | 1550 |
| GPX1614 | 439 | 1939 |
| GPX1700 | 596 | 1842 |
| GPX1980 | 596 | 1842 |
Additional GPX Model References
The following eight model names are included in the supplied historical catalog, but HC and VC dimensions were not provided for them.
| Bell & Gossett Model | HC (mm) | VC (mm) |
|---|---|---|
| GPX4A | — | — |
| GPX35 | — | — |
| GPX47 | — | — |
| GPX7A | — | — |
| GPX37 | — | — |
| GPX62 | — | — |
| GPX22 | — | — |
| GPX43 | — | — |
Glued and Glueless Retention in GPX Equipment
An existing GPX exchanger may use adhesive-bonded seals or a suitable mechanical retention design. The replacement must follow the correct groove geometry and plate-edge features.
During identification, photograph the original seal attachment, including any tabs, clips and adhesive residue. Do not assume that every GPX model supports both systems.
- Identify the fastening method before ordering.
- Inspect clips and locating features.
- Confirm the correct gasket route around all ports.
- Use approved preparation and installation procedures.
- Distinguish gasket curing from service temperature rating.

Request Bell & Gossett GPX Replacement Gaskets
Send the full GPX model, equipment nameplate, original plate and gasket photographs, fluid information, required material and order quantity. These details help evaluate replacement fit and prepare a quotation.
Submit GPX Gasket Enquiry →
Prepare GPX Gasket Spares Before Equipment Shutdown
A scheduled plate-pack inspection often requires replacement sealing components to be ready before the exchanger is opened. Uncertain gasket identification can delay reassembly.
Record the installed equipment population, plate count, gasket material and maintenance scope. Check the quantity needed for every distinct model and special plate position.
- Confirm the full installed GPX model.
- Differentiate plate-pack configurations.
- Specify individual seals or full gasket sets.
- Identify critical shutdown dates.
- Agree delivery and any stock arrangement in the order.
What to Verify Before Approving Replacement Gaskets
Geometry
Plate groove, port rings, clips, dimensions and full model suffix.
Material
Actual compound, fluid compatibility, temperature range and cleaning exposure.
Documentation
Relevant inspection, material and commercial requirements for the specific order.
The supplied legacy record also refers to post-curing at 160°C for four hours, ISO9001:2000 and a one-year warranty. These statements require current order-specific verification.
Frequently Asked Questions
1. Are these original Bell & Gossett OEM gaskets?
No. This category covers independent aftermarket replacement components. The Bell & Gossett name is used to identify existing equipment.
2. Are GPX models with the same HC/VC dimensions interchangeable?
Not necessarily. Port-center spacing is one identifier; the complete plate profile, gasket groove, frame variant and sealing path must also match.
3. Can a GPX heat exchanger use clip-on instead of glued gaskets?
Only when the exact plate and approved replacement configuration support the intended retention system.
4. Is one EPDM or NBR compound suitable for all GPX units?
No. The compound must be selected for the actual process fluid, temperature, cleaning chemistry and service requirements.
5. What documents are needed for a GPX gasket quotation?
Provide the equipment model and suffix, nameplate, plate and gasket photos, process conditions, material specification and required quantity.
Replacement Plates, Gaskets and Complete Heat Exchangers
A plate-pack maintenance project may reveal problems beyond worn elastomers. Inspect the corresponding plates, port surfaces and frame condition before deciding the final replacement scope.
As one of the most professional bell & gossett gaskets manufacturers and suppliers in China, we have world-leading production equipment and strong manufacturing capabilities. We warmly welcome you to wholesale advanced bell & gossett gaskets made in China here from our factory. Customized orders are welcome.
Bell Gossett Compatible Gaskets, Bell Gossett NBR Gaskets, Bell Gossett Plate Heat Exchanger Gaskets