Funke Replacement Plates

Funke Replacement Plates

Replacement plates for identified Funke plate heat exchanger configurations.
Supports targeted replacement of corroded, cracked, deformed or damaged plates.
Plate outline, ports, corrugation and gasket groove are checked before production.
Material selection considers process fluids, chlorides, temperature and cleaning chemicals.
Individual plates, matched positions and maintenance quantities can be evaluated.
Sample photographs and measurements support unidentified or legacy plate matching.
Compatible Funke gaskets can be included according to sealing requirements.
Independently manufactured aftermarket components, not original Funke products.
Send Inquiry
Description
Targeted Plate-Pack Repair

When Should a Funke Heat Exchanger Plate Be Replaced?

Funke replacement plates are used when inspection identifies damage that cleaning or gasket replacement cannot correct. Typical reasons include perforation, cracking, deep corrosion, permanent deformation, damaged ports and unusable gasket grooves. Each replacement must reproduce the installed plate's geometry, material and plate-pack position.

Localized Plate Damage

Selected replacement may be practical when the failed plate positions can be identified and the remaining plate pack is still serviceable.

  • Isolated pinholes or corrosion damage
  • Cracks near ports or formed areas
  • Bent edges or damaged hanging points
  • Distorted gasket grooves or sealing surfaces

Widespread Plate-Pack Damage

Multiple failures may indicate unsuitable material, aggressive cleaning, pressure shock, improper compression or advanced deterioration across the pack.

  • Inspect more than the visibly leaking plate
  • Compare damage on the hot and cold sides
  • Review fluid chemistry and operating history
  • Determine whether a larger replacement set is needed
Replacement Specification

Information Required to Match Funke Replacement Plates

The equipment model is useful, but the installed plate and its position should also be verified before production.

Equipment data Funke heat exchanger model, serial information, nameplate photograph and current plate quantity.
Plate outline Overall length and width, corner shape, hanging arrangement and frame contact features.
Port layout Port diameter, port-center distances and the required combination of open or closed ports.
Corrugation geometry Pressing pattern and orientation must create the intended channel with the adjacent plates.
Gasket interface Gasket groove profile, sealing path and attachment design must accept the matching gasket.
Plate material Confirm the existing alloy and verify it against both fluids, temperature and cleaning chemicals.
Plate position Identify start, channel, turning or end positions where applicable; port openings may differ.
Order quantity State the number required for each configuration and whether compatible gaskets are also needed.

Compatibility notice: These are independently manufactured aftermarket replacement plates. "Funke" identifies the intended equipment compatibility only and does not indicate manufacture or authorization by the brand owner.

Failure Assessment

Use the Damaged Plate to Define the Replacement

Record the damage before cleaning or disposal. Its appearance and position can reveal which operating conditions require further review.

01

Corrosion or Pinholes

Localized metal loss can indicate chlorides, incompatible chemistry, deposits or unsuitable cleaning conditions.

02

Cracking

Cracks near ports or deeply pressed areas require review of pressure variations, material condition and operating history.

03

Deformation

Bent or flattened areas can prevent uniform plate support and gasket compression inside the closed frame.

Photograph both plate faces, mark the fluid side, record the plate-pack position and describe any recurring leakage or pressure event.

Material Review

Do Not Repeat a Material-Related Failure

The existing material provides a starting point. When corrosion caused the failure, verify whether operating conditions changed before ordering the same alloy.

Stainless Steel

Commonly evaluated for compatible water, HVAC, food-processing and industrial duties. Chlorides, pH and temperature remain important.

Titanium

Often considered for seawater or chloride-bearing media where confirmed conditions require greater corrosion resistance.

Specialized Alloys

Nickel-based or other materials may be evaluated when standard plate materials are unsuitable for the process chemistry.

Include both fluid compositions, concentration, chlorides, normal and maximum temperatures, operating pressure and cleaning chemicals in the inquiry.

Identification Process

Prepare a Replacement Plate Inquiry

1

Record the Nameplate

Photograph the Funke equipment nameplate and note the model, serial information and plate quantity.

2

Preserve the Plate Sequence

Record orientation, port configuration and position before removing plates from the frame.

3

Clean a Sample

Remove deposits carefully so the markings, corrugations, ports and gasket groove remain visible.

4

Photograph Both Faces

Take square full-plate images and close-ups of ports, corners, hanging points and damaged areas.

5

Measure Key Features

Provide overall dimensions, port diameter, center distances and any material or thickness markings.

6

Describe the Requirement

List operating conditions, plate positions, quantity, gasket needs and destination country.

Replacement Scope

Individual Plates or a Larger Maintenance Set?

The order scope should reflect the damage pattern, remaining plate condition and certainty of the recorded plate sequence.

Individual Replacement

Suitable for evaluation when damage is localized and the exact plate configuration can be identified.

Matched Positions

Position-specific plates may be required when port openings, corrugation direction or gasket paths differ.

Larger Replacement Set

Consider a broader set when numerous plates show corrosion, thinning, deformation or uncertain serviceability.

Receiving and Installation

Checks Before the Plate Pack Returns to Service

Confirm the supplied plate, plate position and gasket arrangement before dismantling the exchanger for installation.

Receiving Inspection

  • Compare plate geometry with the approved sample
  • Verify material, plate positions and quantities
  • Inspect edges, ports and hanging features
  • Check the gasket groove for transport damage
  • Keep different plate configurations labeled

Plate-Pack Assembly

  • Restore the recorded sequence and orientation
  • Use gaskets matched to the groove and fluids
  • Clean all sealing surfaces before closing
  • Tighten the frame evenly to the required dimension
  • Recommission gradually while checking for leakage
Manufacturing Support

Replacement Plate Supply for Maintenance and Distribution

WTSML manufactures plate heat exchanger components in a 3,500 m² facility with precision stamping, rubber molding, CNC machining and final-inspection workshops. Production processes operate under an ISO 9001-certified quality management system.

Technical Review

Plate identification, dimensions, damage and operating conditions are reviewed before the specification is confirmed.

Combined Spare Parts

Replacement plates and compatible Funke gaskets can be evaluated together for plate-pack maintenance.

OEM Order Options

Private labeling and customized packaging are available according to confirmed purchasing requirements.

Buyer Questions

Funke Replacement Plates FAQ

Can one damaged Funke heat exchanger plate be replaced?

An individual plate may be replaceable when its geometry, material, port configuration and plate-pack position can be identified. The remaining plates, gaskets and frame should also be inspected.

What information is required to match a Funke replacement plate?

Provide the equipment nameplate, photographs of both plate faces, overall dimensions, port measurements, visible markings, existing material, plate position and required quantity.

Should a corroded plate be reordered in the same material?

Not automatically. If corrosion caused the failure, review both fluids, chlorides, concentration, temperature and cleaning chemicals before confirming the replacement material.

Does the Funke model number identify every required plate?

Not always. Plate packs can include different corrugation patterns, orientations, port configurations and terminal positions. Sample details and plate-pack records should also be checked.

Can matching gaskets be supplied with Funke replacement plates?

Compatible gaskets can be evaluated with the plates. Provide the gasket attachment method, process fluids, operating temperature and cleaning conditions.

Are these replacement plates manufactured by Funke?

No. They are independently manufactured aftermarket components intended for verified Funke heat exchanger configurations. The Funke name identifies equipment compatibility only.

Identify the Correct Funke Replacement Plate

Send the equipment nameplate, plate photographs, dimensions, damage details, material, operating conditions, quantity and destination country.

Request Plate Matching & Quote

Hot Tags: funke replacement plates, China funke replacement plates manufacturers, suppliers

Send Inquiry
Send Inquiry